Generally, having a voltage difference between connected equipment isn't the safest thing, right, but...

Since the ground and power source is the same, the voltages on the XLRs should be regulated appropriately by each piece of equipment and are signal based voltages, and everything is cage grounded I don't see how this wouldn't work or be sufficiently safe unless someone was touching the circuits?
davidjohnlee
There should be no voltage at the XLRs other than the signal voltage coming from the source. The voltages at the XLRs will hit a maximum of 24V, and that will be coming from your mixer in the form of signal.

To avoid any unwanted voltages occurring at the signal contact points, all equipment should share a common ground. This is not to say they need to be grounded at the same location but rather that they all are connected to the same ground source, be it building ground or generator ground, via their power cords. The voltages going to each piece of gear will be applied between the power input legs, which are independent from the signal and ground. These power inputs are within the PowerCON connectors. The PowerCON connector also incorporates the primary ground connection to the amplifier. The ground connection within the XLR is a signal ground and is used primarily to shield the signal wires from interference. Ideally there should be no difference in potential between any two ground points however if one piece of gear is on the end of a long extension cord and the other is not, there can be a difference in ground potential. You NEVER want the burden of carrying the ground to fall upon your signal cables. It should always be carried through the heavier gauge wire within the power cable.

On a generator, at least in the US and perhaps other places using 120V power, each hot leg usually supplies 120V between hot and neutral. X-N, Y-N and, in a 3-phase, Z-N. Between the hot legs, X-Y, or in 3-phase also between X-Z and Y-Z you will see 208V. If the hot-hot voltage is at 240V, the hot-neutral voltage will also be higher than 120V, and some gear won’t work over 130V, so it may be necessary to turn the generator’s voltage down when running combined 120 and 240V loads. Measure the voltage between the hot and neutral and turn the generator down until the voltage is below the maximum of the lowest specified equipment in use. The result is likely to provide less than 240V between the hot legs but usually at least 200V. Most 240V specified gear will run on 200-250V. The usable power is sourced between a hot and a neutral or between 2 hots, so provided the generator is loaded relatively evenly between the X and Y, or the X, Y and Z, any individual piece can be powered with either voltage.

David Lee
abradford889
Great tips 👍
Reply